This site uses cookies for functional purposes. To continue please read and agree to our Data Privacy.

By closing this message, you consent to our use of cookies on this device.

  1. Kevin Dufresne
  2. Proficloud
  3. Friday, 16 March 2018
  4.  Subscribe via email

Hi,

how do we add plugin from grafana on our TSD analytics, grafana plugin site said we should use the CLI, but were to start it in our proficloud console ?

 

thanks

 

 

 

Kevin Dufresne

Nivek Automatisation Inc.

 

Dennis Proficloud Team Accepted Answer Pending Moderation
0
Votes
Undo

Hi,

generally it is not possible to install plugins by your own.

Which plugin do you need? Then we can check this whether it is possible to install it.

 

@All: Please send us requests for Plugins on this way, then we check it, whether it is possible to install. Thanks!

 

 

Regards,

Dennis 


Phoenix Contact Electronics Headquarter - Support Center

  1. more than a month ago
  2. Proficloud
  3. # 1
Kevin Dufresne Accepted Answer Pending Moderation
0
Votes
Undo

Hi, thanks for the answer,

I didn't need a specific plugin, I'm trying the proficloud to understand how it work, and the possibillity of the system, so I can offer the service to my customer.

So if I need something for a project, I can ask if it can be add to my proficloud ?

 

 

 

 

Kevin Dufresne

Nivek Automatisation Inc.

 

  1. more than a month ago
  2. Proficloud
  3. # 2
Dennis Proficloud Team Accepted Answer Pending Moderation
0
Votes
Undo

Sure, you can always ask for help and anything else.

We will check it whether it is possible :-)

So if you have any question, just let us know!

 

Regards,

Dennis 


Phoenix Contact Electronics Headquarter - Support Center

  1. more than a month ago
  2. Proficloud
  3. # 3
rrichter Accepted Answer Pending Moderation
0
Votes
Undo

Hi

Here in Brazil we have a customer that are testing to using a cloud iot gateway in his machines and futuretly will give access to TSD for his customers.

We would like know if is possible install the "Pie Chart" plugin?

Is it possible customizer the logo and background?

Thanks

  1. more than a month ago
  2. Proficloud
  3. # 4
avladut@phoenixcontact.com Accepted Answer Pending Moderation
0
Votes
Undo

Hello all,

Our customers ask about "Alert Notification" and "Reporting".

I understood that Reporting in not really possible but it is possible to implement Alerting Engine & Rules in our Grafana?

  1. more than a month ago
  2. Proficloud
  3. # 5
Dennis Proficloud Team Accepted Answer Pending Moderation
0
Votes
Undo

Hi,

the Plugin "Pie Chart" should be available soon in the ProfiCloud.

But it is nt possible to customize the Logo or background.

Maybe you can send me an Mail or your E-Mail Adress, then we can talk a bit and maybe will find another way around.

 

Best regards,

Dennis 


Phoenix Contact Electronics Headquarter - Support Center

  1. more than a month ago
  2. Proficloud
  3. # 6
Dennis Proficloud Team Accepted Answer Pending Moderation
0
Votes
Undo

About the Reporting and Alarming.

The Alarming feature will coming. But I can not actually gibe you a verified date.

 

Best regards,

Dennis


Phoenix Contact Electronics Headquarter - Support Center

  1. more than a month ago
  2. Proficloud
  3. # 7
rrichter Accepted Answer Pending Moderation
0
Votes
Undo

Hi Dennis

The customer asked me about the functionality on grafana to do calculation between some metrics.

Calculate difference between two metric and divide two metrics.

Thank you...

  1. 3 weeks ago
  2. Proficloud
  3. # 8
Dennis Proficloud Team Accepted Answer Pending Moderation
0
Votes
Undo

Hi,

as we use Kairos as datasource, it is not possible at the moment to do calculations between some metrics.

You can do some Aggregations and math operations within one metric.

But this feature is on track, but I cannot give you a timeline, when it could be possible to use this feature.

 

If you have any other question, just let us know!

 

Best regards,

Dennis 


Phoenix Contact Electronics Headquarter - Support Center

  1. 2 weeks ago
  2. Proficloud
  3. # 9
  • Page :
  • 1


There are no replies made for this post yet.
However, you are not allowed to reply to this post.

We have 55 guests and 2 members online