Backups General information Backup and restore mechanisms are used for fast recommissioning after a possible system failure or device reset. Previously backed up data is transferred to the same PLCnext device and the original status is restored. In this version the PLCnext Backup app is responsible… Read More
Function block for gathering SNMP values from managed switches Available with AXC F 2152 and AXC F 3152 General concept By means of this function block, SNMP values from managed switches with up to 8 ports can be read directly by the PLC via the SNMP protocol. arrPartnerList The IP addresses… Read More
Function blocks for data synchronization Available with AXC F 2152 and AXC F 3152 General concept At the Applicative System Redundancy, the same application program is in operation on the two redundant PLCs (First PLC and Second PLC) but only one PLC (either First or Second) controls the process. By means of the ASR_ContrRed_2152 or… Read More
Function block for controller redundancy Available with AXC F 2152 and AXC F 3152 This topic describes the redundancy feature for use with PLCnext Control AXC F 2152 or AXC F 3152 on an applicative base. Note: For hardware-based redundancy with a pair of PLCnext Control RFC 4072R, see System redundancy with RFC 4072R. General concept The communication between the two PLCs necessary for controller… Read More
Engineering software for applicative-redundant systems Configuring the IP addresses with PLCnext Engineer The PROFINET system redundancy needs to be activated and parameterized. For a detailed description on how to do this, see Configuring the IP settings. Activate PROFINET system redundancy A Select Redundancy type… Read More
Function block for gathering port states from Axioline F PROFINET bus couplers Available with AXC F 2152 and AXC F 3152 General concept By the means of this function block the port states from PROFINET bus couplers of the type AXL F BK PN TPS can be read directly by the PLC via PROFINET… Read More
Notification Logger Use Case The Notification Logger enables saving of notifications in a database so the they can be used for analyzing firmware and applications. Saved notifications can be queried via RSC interfaces. The Logger Archives offer functions for acquiring and filtering of incoming notifications as well… Read More
Functions and applications – Overview Functions and applications are built-in benefits for programmers that come with the PLCnext Runtime System. Depending on the firmware release on your PLCnext Control, the set of features can be different. Here you will find a description to every function or application: Notifications Alarms Real-time… Read More
Administration – GDS tab On the GDS tab you make all settings around the GDS (Global Discovery Server). GDS support In the GDS support area you specify whether you want to use a GDS or not. You also specify whether you want to use the internal… Read More
Create connection To create a new connection, click the + CREATE CONNECTION button. A new window opens. Enter a name. Chose the type and enter the IP address. Click the CONNECT button. The window extends. If the connection was successful,… Read More